* Note the table below is the metric unit table
Product Code | Displacement [cm³/rev] |
Max. Speed [RPM] | Max. Flow [l/min] | Max. Torque [Nm] | Max. Pressure [bar] | |||||
---|---|---|---|---|---|---|---|---|---|---|
cont. | inter. | cont. | inter. | cont. | inter. | cont. | inter. | peak | ||
CE 120 | 121 | 360 | 490 | 45 | 61 | 322 | 356 | 207 | 224 | 241 |
CE 160 | 162 | 370 | 470 | 61 | 76 | 424 | 501 | 207 | 224 | 241 |
CE 200 | 204 | 300 | 370 | 61 | 76 | 525 | 593 | 207 | 224 | 241 |
CE 230 | 232 | 260 | 320 | 61 | 76 | 559 | 646 | 207 | 224 | 241 |
CE 260 | 261 | 260 | 350 | 68 | 91 | 706 | 760 | 207 | 224 | 241 |
CE 300 | 300 | 250 | 320 | 76 | 95 | 802 | 862 | 207 | 224 | 241 |
CE 350 | 348 | 220 | 270 | 76 | 95 | 904 | 1017 | 207 | 224 | 241 |
CE 375 | 375 | 200 | 250 | 76 | 95 | 972 | 1040 | 207 | 224 | 241 |
CE 470 | 465 | 160 | 200 | 76 | 95 | 1040 | 1153 | 172 | 189 | 207 |
CE 540 | 536 | 140 | 170 | 76 | 95 | 1003 | 1209 | 138 | 172 | 207 |
CE 750 | 748 | 100 | 130 | 76 | 95 | 1082 | 1237 | 103 | 121 | 138 |
Performance data is typical. Performance of production units varies slightly from one motor to another. Running at intermittent ratings should not exceed 10% of every minute of operation.
General
Temperature Range -30°C – 85°C | Optimal Viscosity20 – 43 cSt | FiltrationMin. ISO 17-14 |