* Note the table below is the metric unit table
Product Code | Displacement [cm³/rev] |
Max. Speed [RPM] | Max. Flow [l/min] | Max. Torque [Nm] | Max. Pressure [bar] | |||||
---|---|---|---|---|---|---|---|---|---|---|
cont. | inter. | cont. | inter. | cont. | inter. | cont. | inter. | peak | ||
WM 008 | 8.4 | 1864 | 2293 | 16 | 20 | 11 | 14 | 100 | 140 | 200 |
WM 012 | 13.1 | 1521 | 1871 | 20 | 25 | 17 | 22 | 100 | 140 | 200 |
WM 020 | 20.1 | 989 | 1229 | 20 | 25 | 26 | 34 | 100 | 140 | 200 |
WM 032 | 31.8 | 622 | 767 | 20 | 25 | 40 | 55 | 100 | 140 | 160 |
WM 040 | 40.2 | 495 | 620 | 20 | 25 | 49 | 64 | 100 | 140 | 160 |
WM 050 | 50.3 | 397 | 487 | 20 | 25 | 59 | 81 | 100 | 140 | 160 |
Performance data is typical. Performance of production units varies slightly from one motor to another. Running at intermittent ratings should not exceed 10% of every minute of operation.
General
Temperature Range -30°C – 85°C | Optimal Viscosity20 – 43 cSt | FiltrationMin. ISO 17-14 |